Micro Spectrophotometer TRMS-604 works as a new type of full-wavelength spectrophotometer. With the mode of USB output or network transfer data, with an electronic manual. Delivers with a wavelength range of 190 to 850nm, with the accuracy of ± 1 nm. It uses a liquid column to recognize the irregular function. Device Platform designed with Stainless steel and quartz fiber, it outcomes with a Light source as long life pulsed xenon flash lamp.

$1922

Specifications
Wavelength Range 190 to 850 nm
Wavelength Accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Repeatability <± 0.5 nm
Light Path 1 mm, 0.05 mm (optical path automatic conversion)
Nucleic Acid measurement range 0.2 to 37500 mg / μl (sa DNA)
Protein measurement range 0.01 to 1120 mg / ml (BSA)
sample volume requirements 0.3 to 2 μl
Absorbance Accuracy 1% (0.76 absorbance at 350 nm)
Absorbance Range 0.002 to 300 Abs (equivalent to 10mm path length)
Sample measurement time less than 3s
Sample base material stainless steel and quartz fiber
Light Source long life pulsed xenon flash lamp
Detector 2048(CMOS) element linear silicide CCD array
Features
  • Users can accept measurement result data and custom methods directly in spreadsheet mode
  • 32GB of storage space is pre-installed
  • Integrated fibre to prevent fibre breakage due to external force collision, which results in hectic measurement results
  • There is no need to warm up, start testing whenever you want
  • Built-in Win10 system, built-in 7-inch high-definition display, full touch operation
  • Stainless steel and quartz fibre used for the platform
  • Using a liquid column to identify abnormal function
  • The built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
  • Two USB ports can be connected to a variety of devices
  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1329

  • Light Path: 1mm
  • sample Volume: 1 to 2μL
  • Detection Range: 190 to 850 nm

$1963

  • Optical Path: 1/0.5/0.05 mm automatic conversion
  • Optical Range: 190 to 1100 nm
  • Sample Volume: 0.3 to 2.0 μl

$1334

  • Wavelength scanning Range: 190 to 850 nm
  • Wavelength Accuracy: ±1 nm
  • Optical Path: 1/0.5/0.05 mm automatic conversion

$1687

  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: £ ±0.5 nm
  • Wavelength Repeatability: £ 0.3 nm (single direction)

$1980

  • Wavelength range : 190 to 900 nm
  • Spectral bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength: ±0.15 nm

$1536

  • Analysis Principle: Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range: Any element from Na(11)-U(92)
  • Minimum Measuring Limit: Cd/Hg/Br/Cr/Pb≤2 ppm

$1537

  • Exciting Optical Filters: Interface optical filter (10 nm bandwidth)
  • Wavelength: 365 nm
  • Emission Monochromatic: C-T diffraction grating (EM 200 to 900 nm )

$1066

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100nm

$1833

  • Spectrum Bandwidth: 2 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1665

  • Spectrum Bandwidth: 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1573

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100 nm

$1906

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1586

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1799

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1913

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1170

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1082

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1169

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1218

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1359

  • Photometry: Single beam
  • Monochromatic Type: Littrow
  • Focal Length: 160 mm

$1186

  • Wavelength Range: 900 to 1700 nm
  • Wavelength  Accuracy: ±1 nm
  •  Wavelength Reproducibility : ≤1 nm

$1148