Double Beam UV VIS Spectrophotometer TRDUV-604 is a double-beam optical system with blazed holographic gratings. It has a sophisticated power protection system, a wavelength range of 190 to 1100 nm, a bandwidth of 2 nm, and an accuracy of 0.3 nm. it performs admirably in qualitative testing with a photometric display range of 0.0–200.0 % T, -0.301 to 4.000 A, 0.000 to 9999 C, and an accuracy of 0.3 % T (0 to 100 % T), 0.002A (0 to 0.5A), and 0.004A, (0.5A to 1A). It comes with a USB interface.

$1833

Specifications
Monochromatic type Czerny turner
Focal length 160 mm
Wavelength Range 190 to 1100nm
Band Width 2 nm
Wavelength Accuracy ±0.3 nm
Wavelength Repeatability ≤0.01 nm
Photometric Display Range 0.0 to 200 .0% T, -0.301 to 4.000 A, 0.000 to 9999 C
Photometric Accuracy ±0.3% T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5A to 1A)
Photometric Repeatability 0.15% T(0 to 100%T), ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
Photometric Mode T,A,C,E
Stray Light ≤0.03% τ (220nm NaI, 360nm NaNO2)
Stability 0.0005A/h@500 nm
Detector Import Silicon Photodiode
Scanning speed Fast-medium-slow
Power Requirement AC220V±22 50Hz±1Hz,200W
Baseline Flatness ≤0.002A(200 to 1090 nm)
Grating 1200 lines/mm
Drifting ≤0.0009 Abs/30 min (250 nm and 500 nm after 2h warm-up)
Dimensions(W×D×H) 74×63×45 Cm
Weight 35    Kg
Features
  • The blazed hologram gratings are used in the dual-beam UV VIS Spectrophotometer
  • Designed with an 8-inch color touch screen, advanced user interface, powerful functions, and simple operation
  • The equipment performs well in qualitative and quantitative testing due to its powerful functions, such as
  • Examine the entire spectrum
  • Linear regression analysis
  • Extensive frequency searching
  • Direct reading with concentration
  • Persistence of time-based kinetics
  • Measurement of multiple wavelengths
  • A sophisticated power protection system is built into the equipment
  • It has a large internal memory and can hold test results, image data, regression analysis, and correction data. As a result, when turned on, it performs a quick initialization
  • Connected with printer, which can print results or draw curves from spectral scanning, fixed wavelength time-based scanning, and linear repression
  •  The device can be connected to a PC via a USB, which not only improves performance in data testing and spectrum scanning but also expands the memory to save more testing results
  • Spectrum Bandwidth: 2 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1665

  • Spectrum Bandwidth: 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1573

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100 nm

$1906

  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: £ ±0.5 nm
  • Wavelength Repeatability: £ 0.3 nm (single direction)

$1980

  • Wavelength range : 190 to 900 nm
  • Spectral bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength: ±0.15 nm

$1536

  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1922

  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1329

  • Light Path: 1mm
  • sample Volume: 1 to 2μL
  • Detection Range: 190 to 850 nm

$1963

  • Optical Path: 1/0.5/0.05 mm automatic conversion
  • Optical Range: 190 to 1100 nm
  • Sample Volume: 0.3 to 2.0 μl

$1334

  • Wavelength scanning Range: 190 to 850 nm
  • Wavelength Accuracy: ±1 nm
  • Optical Path: 1/0.5/0.05 mm automatic conversion

$1687

  • Analysis Principle: Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range: Any element from Na(11)-U(92)
  • Minimum Measuring Limit: Cd/Hg/Br/Cr/Pb≤2 ppm

$1537

  • Exciting Optical Filters: Interface optical filter (10 nm bandwidth)
  • Wavelength: 365 nm
  • Emission Monochromatic: C-T diffraction grating (EM 200 to 900 nm )

$1066

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1586

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1799

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1913

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1170

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1082

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1169

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1218

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1359

  • Photometry: Single beam
  • Monochromatic Type: Littrow
  • Focal Length: 160 mm

$1186

  • Wavelength Range: 900 to 1700 nm
  • Wavelength  Accuracy: ±1 nm
  •  Wavelength Reproducibility : ≤1 nm

$1148