Single Beam UV VIS Spectrophotometer TRSUV-605is a small device with a 7-inch multi-color touch screen. It has an automatic wavelength range of 190 to 1100 nm as well as a bandwidth of 2 nm. Having patented technology that allows for simple and effective human-computer interaction with a clear display of test data It has a photometric range of 0.0 to 200.0 % T, -0.301 to 4.000A, and 0.000 to 9999 C with an accuracy of 0.3 % T, 0.002Abs (0 to 0.5A) and 0.004Abs (0 to 9999 C) (0.5 to 1A). It includes a sample compartment for 5 to 50 mm cuvettes. Delivered with a wavelength scanning Speed.

$1586

Specifications
Photometry Single Beam
Monochromatic Type Czerny-Turner
Focal Length 160 mm
Grating 1200 lines/mm
Detector Silicon Photocell
Spectrum Bandwidth 2nm
Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 1 nm
Wavelength Repeatability ≤ 0.5 nm
Photometric Range 0.0 to 200.0% T, -0.301 to 4.000A, 0.000 to 9999C
Photometric Accuracy ± 0.3% T, ± 0.002Abs (0 to 0.5 A) ± 0.004Abs (0.5 to 1 A)
Photometric Repeatability ≤ 0.15% T, 0.001Abs (0 to 0.5 A) 0.002Abs (0.5 to 1 A)
Wavelength Scanning Speed Fast, medium, slow
Baseline Flatness ≤ ± 0.003 A(200 to 1090 nm)
Stray Light ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO2)
Noise 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
Baseline Drift ± 0.002 Abs / 30 mins (250 nm and 500 nm after preheating warm-up for 2 hours )
Power AC220 V ± 22 V, 50Hz ± 1Hz, 180 W
Packing Size 630 mm×610 mm×500 mm
Weight 0.16m³, 25 Kg
Features
  • 7-inch multi-color touch screen and patented technology for simple and effective human-computer interaction with clear test data display
  • A built-in thermal printer for printing test results and facilitating the creation and storage of data reports
  • A USB communication port and UV professional data processing software enables data processing and mapping functions
  • The storage of large amounts of data files, and help customers with a second development
  • Sample compartment for 5 to 50mm cuvettes
  • Automatic wavelength selection, which is both quick and accurate
  • Scanning kinetic time scanning, automatic wavelength, linear regression, direct concentration readout, peak detection, regular printing, and so on
  • Power shutdown protection measures that are advanced to memorize detector data and regression
  • To achieve fast initialization, the equation and instrument correction parameters must be known ahead of time
  • Lifelong safety for tungsten and deuterium lamps
  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1799

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1913

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1170

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1082

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1169

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1218

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1359

  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: £ ±0.5 nm
  • Wavelength Repeatability: £ 0.3 nm (single direction)

$1980

  • Wavelength range : 190 to 900 nm
  • Spectral bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength: ±0.15 nm

$1536

  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1922

  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1329

  • Light Path: 1mm
  • sample Volume: 1 to 2μL
  • Detection Range: 190 to 850 nm

$1963

  • Optical Path: 1/0.5/0.05 mm automatic conversion
  • Optical Range: 190 to 1100 nm
  • Sample Volume: 0.3 to 2.0 μl

$1334

  • Wavelength scanning Range: 190 to 850 nm
  • Wavelength Accuracy: ±1 nm
  • Optical Path: 1/0.5/0.05 mm automatic conversion

$1687

  • Analysis Principle: Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range: Any element from Na(11)-U(92)
  • Minimum Measuring Limit: Cd/Hg/Br/Cr/Pb≤2 ppm

$1537

  • Exciting Optical Filters: Interface optical filter (10 nm bandwidth)
  • Wavelength: 365 nm
  • Emission Monochromatic: C-T diffraction grating (EM 200 to 900 nm )

$1066

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100nm

$1833

  • Spectrum Bandwidth: 2 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1665

  • Spectrum Bandwidth: 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1573

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100 nm

$1906

  • Photometry: Single beam
  • Monochromatic Type: Littrow
  • Focal Length: 160 mm

$1186

  • Wavelength Range: 900 to 1700 nm
  • Wavelength  Accuracy: ±1 nm
  •  Wavelength Reproducibility : ≤1 nm

$1148