Spectrophotometer TRNS-601 is having with full automation, presenting with many regular functions, spectrum pre-processing, model test and distract, self-test correction, sample analysis, scanning curve storage, display, comparison, and print. Device analysis software with a laptop. It has a wavelength range of 900 to 1700nm. It has Single-channel whole spectrum scanning. Wavelength Scanning Interval Absorbance with a 1 nm, 4 nm, 8 nm, 16 nm.

$1148

Specifications
Wavelength Range 900 to 1700 nm
Wavelength  Accuracy ±1 nm
 Wavelength Reproducibility  ≤1 nm
Wavelength Scanning Interval Absorbance 1 nm, 4 nm, 8 nm, 16 nm
Reproducibility S/N 0.002 A (at 0.4 A)
Scanning Time ≥ 103 (at 1500 nm)
Application Field ≤2 min
Optical system Liquid dope samples
Detector  grating monochromatic InGaAs
Interface RS232 serial port
Dimensions 570×370×240 mm
Weight 18 Kg
Features
  • The process of quantitatively analyzing the gasoline octane value, antiknock coefficient, and EP value
  • It analysis software with a laptop, full automation, numerous standard functions
  • The correlation for the gas Ron method is very low, at 0.97
  • Easily updated. Fast scan, wavelength calibrated time from 900nm to 1700nm in under 2 minutes
  • SCM technology, built-in, as is auto 0 percent and auto background subtraction
  • It has Single-channel whole spectrum scanning
Download Catalog
  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: £ ±0.5 nm
  • Wavelength Repeatability: £ 0.3 nm (single direction)

$1980

  • Wavelength range : 190 to 900 nm
  • Spectral bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength: ±0.15 nm

$1536

  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1 nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1922

  • Wavelength Range: 190 to 850 nm
  • Wavelength Accuracy: ± 1nm
  • Wavelength Resolution: 2 nm (FWHM at Hg 546 nm)

$1329

  • Light Path: 1mm
  • sample Volume: 1 to 2μL
  • Detection Range: 190 to 850 nm

$1963

  • Optical Path: 1/0.5/0.05 mm automatic conversion
  • Optical Range: 190 to 1100 nm
  • Sample Volume: 0.3 to 2.0 μl

$1334

  • Wavelength scanning Range: 190 to 850 nm
  • Wavelength Accuracy: ±1 nm
  • Optical Path: 1/0.5/0.05 mm automatic conversion

$1687

  • Analysis Principle: Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range: Any element from Na(11)-U(92)
  • Minimum Measuring Limit: Cd/Hg/Br/Cr/Pb≤2 ppm

$1537

  • Exciting Optical Filters: Interface optical filter (10 nm bandwidth)
  • Wavelength: 365 nm
  • Emission Monochromatic: C-T diffraction grating (EM 200 to 900 nm )

$1066

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100nm

$1833

  • Spectrum Bandwidth: 2 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1665

  • Spectrum Bandwidth: 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range: 190 to 1100 nm
  • Monochromatic Type: Czerny-Turner

$1573

  • Monochromatic type: Czerny turner
  • Focal length: 160 mm
  • Wavelength Range: 190 to 1100 nm

$1906

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1586

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1799

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1913

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1170

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1082

  • Photometry: Single Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1169

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1218

  • Photometry: Split Beam
  • Monochromatic Type: Czerny-Turner
  • Focal Length: 160 mm

$1359

  • Photometry: Single beam
  • Monochromatic Type: Littrow
  • Focal Length: 160 mm

$1186